Skip to content

Fault code group

AdBlue / SCR Fault Codes

The SCR (selective catalytic reduction) system injects AdBlue (urea solution) into the exhaust to convert nitrogen oxides into nitrogen and water vapour. The control unit monitors AdBlue level and quality, the pump and dosing valve, the heaters and the conversion efficiency, and stores a fault code when one of them leaves the expected range. On many vehicles the driver is then warned and performance may be limited.

Free pre-checkECU identification and applicable operations without credits
Credit only on successNo charge if it fails
Byte-level checksUnverified results are labelled
PrimeChecksumbuilt-in checksum engine

System

What does this system do?

The SCR (selective catalytic reduction) system injects AdBlue (urea solution) into the exhaust to convert nitrogen oxides into nitrogen and water vapour. The control unit monitors AdBlue level and quality, the pump and dosing valve, the heaters and the conversion efficiency, and stores a fault code when one of them leaves the expected range. On many vehicles the driver is then warned and performance may be limited.

A fault code is a symptom; on its own it does not tell you the cause. First check live data with a diagnostic tool and inspect wiring, connectors and components. A software operation does not replace fault diagnosis and repair.

Code search

Look up a fault code

If the code has its own page you go straight to it; if it is only listed in a group table you go to its row.

Code list

AdBlue / SCR fault codes

DescriptionCode
Reductant Control Module System VoltageP056D
Cold Start SCR NOx Catalyst Inlet Temperature Too LowP05EB
Reductant Heater Control Module Supply VoltageP05ED
Reductant Pump Supply Voltage – Circuit/OpenP05EE
Reductant Pump Supply Voltage – Circuit LowP05EF
Reductant Pump Supply Voltage – Circuit HighP05F0
Reductant Pump Supply Voltage – Stuck OnP05F1
Reductant Pump Supply Voltage – Stuck OffP05F2
Reductant Heater Control Module PerformanceP05F8
Reductant System Malfunction Lamp Control CircuitP065D
Reductant Control Module Internal Temperature Sensor CircuitP06F0
NOx Trap Efficiency Below Threshold (Bank 1)P2000
NOx Trap Efficiency Below Threshold (Bank 2)P2001
Reductant Pump A Stuck OnP201F
Reductant Injection Air Pressure Sensor – CircuitP2037
Reductant Injection Air Pressure Sensor – Range/PerformanceP2038
Reductant Injection Air Pressure Sensor – Circuit LowP2039
Reductant Level Sensor – CircuitP203A
Reductant Level Sensor – Range/PerformanceP203B
Reductant Level Sensor – Circuit LowP203C
Reductant Level Sensor – Circuit HighP203D
Reductant Level Sensor – Intermittent/ErraticP203E
Reductant Level Too LowP203F
Reductant Injection Air Pressure Sensor – Circuit HighP2040
Reductant Injection Air Pressure Sensor – IntermittentP2041
Reductant Temperature Sensor – CircuitP2042
Reductant Temperature Sensor – Range/PerformanceP2043
Reductant Temperature Sensor – Circuit LowP2044
Reductant Temperature Sensor – Circuit HighP2045
Reductant Temperature Sensor – IntermittentP2046
Reductant Injection Valve (Bank 1 Unit 1) – Circuit/OpenP2047
Reductant Injection Valve (Bank 1 Unit 1) – Circuit LowP2048
Reductant Injection Valve (Bank 1 Unit 1) – Circuit HighP2049
Reductant Pressure Sensor – CircuitP204A
Reductant Pressure Sensor – Range/PerformanceP204B
Reductant Pressure Sensor – Circuit LowP204C
Reductant Pressure Sensor – Circuit HighP204D
Reductant Pressure Sensor – Intermittent/ErraticP204E
Reductant System (Bank 1) – PerformanceP204F
Reductant Injection Valve (Bank 2 Unit 1) – Circuit/OpenP2050
Reductant Injection Valve (Bank 2 Unit 1) – Circuit LowP2051
Reductant Injection Valve (Bank 2 Unit 1) – Circuit HighP2052
Reductant Injection Valve (Bank 1 Unit 2) – Circuit/OpenP2053
Reductant Injection Valve (Bank 1 Unit 2) – Circuit LowP2054
Reductant Injection Valve (Bank 1 Unit 2) – Circuit HighP2055
Reductant Injection Valve (Bank 2 Unit 2) – Circuit/OpenP2056
Reductant Injection Valve (Bank 2 Unit 2) – Circuit LowP2057
Reductant Injection Valve (Bank 2 Unit 2) – Circuit HighP2058
Reductant Injection Air Pump Control – Circuit/OpenP2059
Reductant Tank Temperature Sensor – CircuitP205A
Reductant Tank Temperature Sensor – Range/PerformanceP205B
Reductant Tank Temperature Sensor – Circuit LowP205C
Reductant Tank Temperature Sensor – Circuit HighP205D
Reductant Tank Temperature Sensor – Intermittent/ErraticP205E
Reductant System (Bank 2) – PerformanceP205F
Reductant Injection Air Pump Control – Circuit LowP2060
Reductant Injection Air Pump Control – Circuit HighP2061
Reductant Supply Control – Circuit/OpenP2062
Reductant Supply Control – Circuit LowP2063
Reductant Supply Control – Circuit HighP2064
Reductant Quality Sensor – CircuitP206A
Reductant Quality Sensor – Range/PerformanceP206B
Reductant Quality Sensor – Circuit LowP206C
Reductant Quality Sensor – Circuit HighP206D
Reductant Quality PerformanceP207F
Reductant Pump Control – Circuit/OpenP208A
Reductant Pump Control – Range/PerformanceP208B
Reductant Pump Control – Circuit LowP208C
Reductant Pump Control – Circuit HighP208D
Reductant Injection Valve (Bank 1 Unit 1) – Stuck ClosedP208E
Reductant Purge Control Valve – Circuit/OpenP20A0
Reductant Purge Control Valve – PerformanceP20A1
Reductant Purge Control Valve – Circuit LowP20A2
Reductant Purge Control Valve – Circuit HighP20A3
Reductant Injection Air Pressure Control Valve – Circuit LowP20A8
Reductant Heater A Control – Circuit/OpenP20B9
Reductant Heater A Control – PerformanceP20BA
Reductant Heater A Control – Circuit LowP20BB
Reductant Heater A Control – Circuit HighP20BC
Reductant Heater B Control – Circuit/OpenP20BD
Reductant Heater B Control – PerformanceP20BE
Reductant Heater B Control – Circuit LowP20BF
Reductant Heater B Control – Circuit HighP20C0
Reductant Heater C Control – Circuit/OpenP20C1
Reductant Heater C Control – PerformanceP20C2
Reductant Heater C Control – Circuit LowP20C3
Reductant Heater C Control – Circuit HighP20C4
Reductant Heater D Control – Circuit/OpenP20C5
Reductant Heater D Control – PerformanceP20C6
Reductant Heater D Control – Circuit LowP20C7
Reductant Heater D Control – Circuit HighP20C8
Reductant Pressure – Too LowP20E8
Reductant Pressure – Too HighP20E9
SCR NOx Catalyst Efficiency Below Threshold (Bank 1)P20EE
Reductant Consumption – Too LowP20F4
Reductant Consumption – Too HighP20F5
Reductant Level Sensor B – Intermittent/ErraticP21AC
Reductant Tank Cap Switch – Range/PerformanceP24CC
Reductant Purge Control Valve B – Stuck ClosedP24E0
NOx Exceedance – Empty Reagent TankP2BA7
NOx Exceedance – Interruption of Reagent Dosing ActivityP2BA8
NOx Exceedance – Low Reagent ConsumptionP2BAA
NOx Exceedance – Deactivation of EGRP2BAC
NOx Exceedance – NOx Control Monitoring SystemP2BAE

Linked codes have their own page; the others are listed in this table only.

Related operations

Software operations related to this system

Help

Frequently asked questions

What do AdBlue / SCR fault codes indicate?

The SCR (selective catalytic reduction) system injects AdBlue (urea solution) into the exhaust to convert nitrogen oxides into nitrogen and water vapour. The control unit monitors AdBlue level and quality, the pump and dosing valve, the heaters and the conversion efficiency, and stores a fault code when one of them leaves the expected range. On many vehicles the driver is then warned and performance may be limited.

Does switching off a fault code fix the fault?

No. Switching a code off in software does not remove the cause of the fault. Diagnose and repair the fault first. Operations on emission systems such as DTC off are offered only for use permitted by local law (e.g. off-road / motorsport / export).

Where do the code descriptions on these pages come from?

The code titles are based on the generic SAE J2012 / ISO 15031-6 code definitions and written in our own words. Manufacturer-specific codes are not listed. The ECU families come from fault code tables verified in EcuPrime.

Start today

A free account for dealers and tuning pros: upload your file, see which operations work, apply your solution.

Create free account